-40%
WSM01-2 Volt Acquisition Module Data Collector Logger 10V Analog Quantity Input
$ 34.47
- Description
- Size Guide
Description
WSM01-2 Volt Acquisition Module Data Collector Logger 10V Analog Quantity InputFeature:
1. The acquisition module uses a high‑accuracy AD chip, 16‑channel analog voltage input, with stable operation.
2. The input range of analog quantity acquisition is 0-10V, the accuracy can 0.02V, and the data acquisition is fast and accurate.
3. The initial baud rate is 9600 and the station number is 01, and the baud rate and station number can be adjusted by instructions.
4. Use wireless communication to transmit data, which is convenient and safe to use and avoid measurement errors caused by connection.
5. Can be networked with PLC, HMI, PC, etc., and is widely used for signal control of industrial field equipment.
Specification:
Item Type: Voltage Acquisition Module
Model: WSM01-2
Material: Engineering Plastic
Power Supply Voltage: DC 8-30V
Maximum Working Current: 120mA
Application Scenario: Cooperate with the host(PLC, HMI, PC are all available), collect the digital value after voltage signal conversion. Commonly used in industrial equipment monitoring, environmental monitoring and other occasions.
Communication Description:
Read the First Voltage Input (AD1 Input 1V Voltage):
Host Sending: 01/04/0000/0001/31CA/
Station number/function /first address/quantity/check /
Module Return: 01/04/02/0064/B8DB/
Station number/function /bytes/voltage data/check /
Read 1 to 16 Channels Of Voltage Input (16 Channels Of AD input 1V voltage):
Host Send: 01/04/0000/0010/F1 C6/
Station number/function /first address/quantity/check /
Module Return: 01/04/20/0064006400640064006400640064006400640064
Station No./Function /Number of Bytes/Voltage Data 006400640064006400640064/BE29/Check /
Modify Module Parameters (baud Rate, Station Number):
1. The baud rate and station number parameters of this module are stored in the data register, which can be modified by command
2. Modification Of The Baud Rate: Write data (00H~08H corresponding to 9 baud rates) into the module data register 19H (the address corresponding to the baud rate) to modify the baud rate. After the module responds, the baud rate Will be modified, this parameter can be saved after power-off.
The Corresponding Relationship of These 9 Baud Rates is:
00H 600 01H 1200 02H 2400 03H 4800 04H 9600 (default) 05H 19200 06H 38400 07H 57600 08H 115200
Example: Modify the current baud rate to 1200bps
Host Sends: 01 06 00 19 00 01 99 CD
Module Returns: 01 06 00 19 00 01 99 CD
3. Modification of the Station Number: Write data (00H is the broadcast address, 01H is the default address of the module) to the module data register 18H (the address corresponding to the station number) to modify the station number. After the module responds, the station number will be changed. Modify, this parameter can be saved after power-off.
Example: Modify the module whose current station number is 01H to 09H
Host Sends: 01 06 00 18 00 09 C9 CB
Module Returns: 01 06 00 18 00 09 C9 CB
Module returns When the baud rate and station number information is forgotten, you can reset by shorting the TP1 pad on the module to ground (use with caution)
Package List:
1 x Voltage Acquisition Module
We accept PayPal .
We ship item to your PayPal verified address.
Payment must be received within 3 days from the date of purchase.
All the items will be dispatched within one business day by Airmail after the payment is clear.
Most times you will receive your order within 10-30 business days after we transfer your package to the delivery company. We cannot guarantee the delivery timeframe if the post office has any unexpected delays due to holiday, weather, customs, or other conditions. Some countries like Russia, Brazil, or some European countries may take up to 50 days or longer for delivery.
We appreciate your patience if you haven't received items in 30 days(Russian customers may need more patience by reason of the local delivery system and/or customs). If you are concerned in any way, please feel free to contact us via ebay message
instead of leaving negative/neutral feedback or opening a dispute
.
We will make every effort to fix any problem(resend or refund any missing item).
Customs duty is obligation and liability of
citizen
s in your country, so buyer should be responsible for any tax and custom duty incurred. Generally, the delay or failure delivery is sometimes caused by the policy of different customs.
1. Our listing price includes the value of goods,packaging cost,and export
taxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3.
T
he duties are buyers' responsibility
.Please check with your country's
customs office determine what these additional costs will be prior to your
purchase.
4. All disputes arising from the duties will be submitted to ebay for solution.
1. Any questions,
pls. contact us via ebay message or email us.
We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.
2. If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "
5
" in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better.
We strive to keep all our customers satisfy.
We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.